OZONE TEST CHAMBER
Specifications
Exposure Chamber:
|
Dimensions 500 x 500 x 600 (150L).
Ozonised Air Flow 50-300L / min. Maximum of 2 air changes / min. Internal circulation fan to ASTM D1149.600 mm / sec. (2feet / sec). Test Chamber Illumination. Closed loop circulation. |
Test Sample Piece Carrier: |
Static test piece carrier
5 sample frames of variable, adjustable strain. Rotating Carrier 1 Rev / 5mins with spun movement for each frame. Dynamic test peice carrier. 8 samples frame. Adjustable strain 5%, 10%, 15%, 20%, 25%, 40% & 60% Operating frequency 0.5Hz |
Temperature / Humidity Range:
|
Operating range ambient +5 degree + 70 Degree Celsius
Control accuracy +- 1 Degree Celsius Humidity : 10.90% (Control Operational Extra) |
Ozone Concentration:
|
Operational range measured in pphm 25 200. (UP TO 10PPM OPTIONAL EXTRA)
Ozone general through UV Lamp. Ozone recover after sample insertion within 10 minutes |
Ozone Measurement:
|
UV absorption Analyzer
Measurement accuracy +- pphm. Control Accuracy +- 10% of set point. |
HMI Control Recording & Reporting:
|
Touch Button Operation.
HMI display of Ozone / Temp / Humidity. |
Dimensions:
|
ISO 1430-I AND 2 : 1989 (E)
|